Accueil / Produit / Analyseur de CO AQMS-400

Analyseur de CO AQMS-400

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

Téléchargements et ressources

Obtenir un devis maintenant
Description

Présentation du produit

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

Principe

Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

Analyseur de CO AQMS-400 Spécifications techniques

Gamme standard
(0~50)ppm, Expandable
Principe NDIR
Zéro bruit ≤0.1ppm (RMS)
Bruit de portée ≤0.25ppm (RMS)
Limite inférieure de détection ≤0.04ppm (RMS)
Affichage 0.05ppm
Dérive nulle ±0.1ppm
Déviation de portée <0.5% of reading
Linéarité <1%F.S.
Précision <1%
Temps de réponse T90<60s
Débit de l'échantillon (800±80)sccm
Transmission des données 2 channel analog (4~20) mA;

12 digital input/output;

4-way relay output;

Communication RS232/RS485/Ethernet
Température de fonctionnement US EPA Specification 20~30°C

Actual applicable:-5~55°C

Humidité de fonctionnement 0~95%RH
Étalonnage Calibrateur multipoint
Puissance requise 220V AC/50Hz ;

110V AC/60Hz

Dimensions et poids 178(H)x432(W)x597(D)mm, 28kg

Applications polyvalentes dans tous les secteurs

Principales caractéristiques de Analyseur de CO AQMS-400

  • 14 meters optical path to perform high reliability.
  • Five years guarantee on GFC wheel.
  • Compliance with US EPA reference method.
  • Various outputs include ethernet and RS232.
  • User friendly interface with large screen.
  • Diagnostic continu du système avec alarme.
  • Multi-tasking software allows viewing test variables while operating;
  • Compensation de la température et de la pression.
  • Internal data logging with 1 min to 365 day multiple averages.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.

Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Stockage et analyse des données
Les données stockées sont facilement récupérables via le port série ou Ethernet par l'intermédiaire d'un logiciel client PC, ce qui permet aux opérateurs d'effectuer des diagnostics prédictifs et une analyse améliorée des données en suivant les tendances des paramètres.

Pourquoi Analyseur de CO AQMS-400 Se démarque

Foire aux questions

Obtenir un devis maintenant

Débloquez l'analyse de précision avec Analyseur de CO AQMS-400

Prêt à améliorer vos opérations grâce à des solutions d'analyse en ligne de pointe ? Contactez-nous pour obtenir des conseils d'experts, des tarifs ou une démonstration personnalisée.

Envoyez votre demande aujourd'hui

Remplissez le formulaire ci-dessous, et nous vous contacterons dans les plus brefs délais.

Coordonnées
Détails du projet