SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

The FPI SUPEC-7000 Series ICP-MS has successfully resolved the core technology challenges associated with mass spectrometry, including high-temperature gas flow control, multi-stage gradient vacuum, highly sensitive ion interfaces, a distributed collision cell, and a temperature- and humidity-resistant quadrupole mass analyser, among others. The FPI SUPEC-7000 Series ICP-MS boasts excellent sensitivity, a lower detection limit, superior stability and a wider dynamic linear range, making it ideal for the analysis of trace elements in a diverse range of samples.

Discover how the FPI SUPEC-7000 Series ICP-MS can streamline laboratory processes and deliver precise elemental analysis reports in a timely manner.

Téléchargements et ressources

Obtenir un devis maintenant
Description

Présentation du produit

FPI SUPEC-7000 series inductively coupled plasma mass spectrometer offers high sensitivity and reliability.

The SUPEC-7000 Series ICP-MS was developed following the resolution of core technical challenges in mass spectrometer, including the control of high-temperature gases, the utilization of multistage gradient vacuums, the integration of high-sensitivity ion interfaces, the incorporation of distributed collision reaction cells, and the incorporation of a quadrupole mass analyzer with temperature and humidity resistance.

Il est associé à un système de chromatographie liquide, un système de dilution de gaz en ligne, une injection rapide automatique, une oxycombustion, une ablation laser, une injection directe dans l'atmosphère, une injection organique et d'autres technologies spécialisées, et convient à une variété d'applications professionnelles. La combinaison d'Element V, un logiciel professionnel pour spectromètres de masse, avec une bibliothèque de méthodologies standard, un réglage automatique, un mode de fonctionnement guidé et une surveillance visuelle de l'état à tout moment simplifie considérablement l'utilisation du logiciel pour spectromètres de masse, tout en répondant aux besoins étendus des applications en laboratoire.

SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry Spécifications techniques

Applications polyvalentes dans tous les secteurs

Analyse de la spéciation élémentaire

Détection du mercure organique
La LC offre une excellente capacité de séparation, tandis que la lCP-MS présente les avantages d'une sensibilité élevée et d'une limite de détection faible. La combinaison des deux est donc devenue la méthode principale pour la détection du mercure organique.
Analyse de la spéciation de l'arsenic
In the determination of total arsenic and inorganic arsenic in food, the inorganic arsenic in food is extracted by acidic substances, and the target compound separated by LC is determined in SUPEC-7000 Series.
Analyse de la valence du chrome
There are two main forms of chromium, Cr(lll) and Cr(IV), SUPEC-7000 Series is combined with liquid chromatography and anion exchange chromatography column to analyze chromium valence in environmental water.

Sol

According to the limit requirements of various heavy metals in the soil specified in EPA 3050 Band EPA 3051B, SUPEC-7000 Series is used to determine the content of metal elements in standard soil samples, and the matrix effect of soil samples is eliminated by bismuth, indium and antimony internal elements, and the interference correction equation and collision reaction cell are adopted.Technology eliminates interference from isobaric

Géologie

L'analyse des éléments de terres rares a toujours été un domaine important de l'analyse chimique. La détermination précise de la teneur en éléments de terres rares et des relations entre ces éléments revêt une grande importance pour déterminer l'environnement sédimentaire des roches et rechercher des gisements de terres rares. La spectrométrie de masse à plasma inductif (ICP-MS) est largement utilisée pour la détection d'oligo-éléments dans les échantillons géologiques, les produits minéraux et les sédiments aquatiques en raison de sa grande sensibilité et de sa faible interférence de détection.

Eau et déchets

The EPA Method 200.8: ‘Determination of Trace Elements in Waters and Wastes by inductively Coupled Plasma Mass Spectrometry’ especially involves ultra-trace amounts of barium, cadmium, chromium, mercury,s trontium, barium, etc. Measurement of these elements requires the instrument to have excellent sensitivity.The SUPEC-7000 Series can perform accurate measurement of multiple elements in the laboratory, and can be carried by the vehicle to the emergency site to complete the analysis of the above elements.

Principales caractéristiques de SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

Excellente sensibilité

Grâce à une conception innovante de simulation aérodynamique qui améliore l'interface ionique à la jonction entre le plasma thermique et le vide, la sensibilité de l'ICP-MS est considérablement améliorée, avec un gain de 3 à 5 fois. Cette avancée permet d'atteindre des limites de détection aussi faibles que quelques parties par trillion (ppt), ce qui en fait un outil idéal pour l'analyse de matériaux et de réactifs de haute pureté.

Tolérance matricielle exceptionnelle
The remarkable matrix tolerance of the SUPEC 7000 Series enables direct injection of high-salt samples up to 10%. This capability is achieved through thorough fluid simulations of ion interfaces, innovative design featuring two off-axes in the front and at the back, patented collision reaction cells, a robust self-excited all-solid-state ICP ion source, argon online dilution, and other cutting-edge technologies.
Conception innovante axée sur la fiabilité pour une stabilité accrue
The SUPEC 7000 Series stands out as the sole ICP-MS device capable of on-board operation. Its exclusive design features shock absorption and all-solid-state components, ensuring optimal stability. Rigorous testing, including assessments of road load data under varying road conditions while on board vehicles, as well as extensive practical tests covering tens of thousands of kilometers, have validated its exceptional reliability.

Applications multiples

En tant que technique d'analyse rapide multi-éléments largement utilisée dans les industries qui nécessitent l'analyse de grandes quantités d'échantillons et la mesure de plusieurs éléments dans chaque échantillon. Les industries utilisant l'ICP-MS comprennent la surveillance environnementale (eau de rivière, eau potable, eau d'estuaire et eau de mer, déchets, digestats de sols et de sédiments, communautés biologiques, etc.), les tests de routine sur la sécurité alimentaire, l'analyse des matériaux pharmaceutiques et les tests sur les produits de consommation (jouets, textiles, etc.). Parmi les autres industries où l'ICP-MS est largement utilisé, on peut citer la fabrication de semi-conducteurs et de produits chimiques fins, les sciences de la vie, la recherche clinique, la géochimie, l'exploitation minière, la science nucléaire, la recherche sur les matériaux, la métrologie et le monde universitaire.

Pourquoi SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry Se démarque

Foire aux questions

Obtenir un devis maintenant

Débloquez l'analyse de précision avec SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

Prêt à améliorer vos opérations grâce à des solutions d'analyse en ligne de pointe ? Contactez-nous pour obtenir des conseils d'experts, des tarifs ou une démonstration personnalisée.

Produits connexes

Envoyez votre demande dès aujourd'hui

Remplissez le formulaire ci-dessous et nous vous contacterons dans les plus brefs délais.

Informations sur le contact
Détails du projet