SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

The FPI SUPEC-7000 Series ICP-MS has successfully resolved the core technology challenges associated with mass spectrometry, including high-temperature gas flow control, multi-stage gradient vacuum, highly sensitive ion interfaces, a distributed collision cell, and a temperature- and humidity-resistant quadrupole mass analyser, among others. The FPI SUPEC-7000 Series ICP-MS boasts excellent sensitivity, a lower detection limit, superior stability and a wider dynamic linear range, making it ideal for the analysis of trace elements in a diverse range of samples.

Discover how the FPI SUPEC-7000 Series ICP-MS can streamline laboratory processes and deliver precise elemental analysis reports in a timely manner.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

FPI SUPEC-7000 series inductively coupled plasma mass spectrometer offers high sensitivity and reliability.

The SUPEC-7000 Series ICP-MS was developed following the resolution of core technical challenges in mass spectrometer, including the control of high-temperature gases, the utilization of multistage gradient vacuums, the integration of high-sensitivity ion interfaces, the incorporation of distributed collision reaction cells, and the incorporation of a quadrupole mass analyzer with temperature and humidity resistance.

Se combina con un sistema de cromatografía líquida, un sistema de dilución de gases en línea, inyección rápida automática, oxicombustión, ablación por láser, inyección directa en atmósfera, inyección orgánica y otras tecnologías especializadas, y es adecuado para una gran variedad de aplicaciones profesionales. La combinación de Element V, un sistema de software de espectrómetro de masas profesional, con una biblioteca de metodología estándar, sintonización automática, modo de funcionamiento guiado y supervisión visualizada del estado en cualquier momento simplifica enormemente el funcionamiento del sistema de software del espectrómetro de masas, al tiempo que satisface las amplias necesidades de las aplicaciones de laboratorio.

SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry Especificaciones técnicas

Aplicaciones versátiles en todos los sectores

Análisis de especiación elemental

Detección de mercurio orgánico
La LC tiene una excelente capacidad de separación, y la lCP-MS tiene las ventajas de una alta sensibilidad y un bajo límite de detección, por lo que la combinación de ambos se ha convertido en el método dominante para la detección de mercurio orgánico.
Análisis de especiación del arsénico
In the determination of total arsenic and inorganic arsenic in food, the inorganic arsenic in food is extracted by acidic substances, and the target compound separated by LC is determined in SUPEC-7000 Series.
Análisis de la valencia del cromo
There are two main forms of chromium, Cr(lll) and Cr(IV), SUPEC-7000 Series is combined with liquid chromatography and anion exchange chromatography column to analyze chromium valence in environmental water.

Suelo

According to the limit requirements of various heavy metals in the soil specified in EPA 3050 Band EPA 3051B, SUPEC-7000 Series is used to determine the content of metal elements in standard soil samples, and the matrix effect of soil samples is eliminated by bismuth, indium and antimony internal elements, and the interference correction equation and collision reaction cell are adopted.Technology eliminates interference from isobaric

Geología

O El análisis de elementos de tierras raras siempre ha sido un campo importante del análisis químico. La determinación precisa del contenido de elementos de tierras raras y la interrelación entre los elementos son de gran importancia para determinar el entorno sedimentario de las rocas y buscar yacimientos de tierras raras. La espectrometría de masas con plasma acoplado inductivamente (lCP-MS) se utiliza ampliamente en la detección de oligoelementos en muestras geológicas, productos minerales y sedimentos acuáticos debido a su alta sensibilidad y baja interferencia de detección.

Agua y residuos

The EPA Method 200.8: ‘Determination of Trace Elements in Waters and Wastes by inductively Coupled Plasma Mass Spectrometry’ especially involves ultra-trace amounts of barium, cadmium, chromium, mercury,s trontium, barium, etc. Measurement of these elements requires the instrument to have excellent sensitivity.The SUPEC-7000 Series can perform accurate measurement of multiple elements in the laboratory, and can be carried by the vehicle to the emergency site to complete the analysis of the above elements.

Características principales de SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

Excelente sensibilidad

Gracias a un innovador diseño de simulación aerodinámica que mejora la interfaz iónica en la unión del plasma térmico y el vacío, la sensibilidad de la ICP-MS mejora significativamente entre 3 y 5 veces. Este avance permite límites de detección tan bajos como partes por billón (ppt), lo que lo hace ideal para analizar materiales y reactivos de gran pureza.

Tolerancia excepcional a la matriz
The remarkable matrix tolerance of the SUPEC 7000 Series enables direct injection of high-salt samples up to 10%. This capability is achieved through thorough fluid simulations of ion interfaces, innovative design featuring two off-axes in the front and at the back, patented collision reaction cells, a robust self-excited all-solid-state ICP ion source, argon online dilution, and other cutting-edge technologies.
Diseño innovador orientado a la fiabilidad que mejora la estabilidad
The SUPEC 7000 Series stands out as the sole ICP-MS device capable of on-board operation. Its exclusive design features shock absorption and all-solid-state components, ensuring optimal stability. Rigorous testing, including assessments of road load data under varying road conditions while on board vehicles, as well as extensive practical tests covering tens of thousands of kilometers, have validated its exceptional reliability.

Múltiples aplicaciones

Como técnica rápida de análisis multielemento ampliamente utilizada en industrias que requieren el análisis de grandes cantidades de muestras y la medición de múltiples elementos dentro de cada muestra. Entre las industrias que utilizan ICP-MS se incluyen el control medioambiental (agua de río, agua potable, agua de estuario y de mar, residuos, digestiones de suelos y sedimentos, comunidades biológicas, etc.), pruebas rutinarias de seguridad alimentaria, análisis de material farmacéutico y pruebas de productos de consumo (juguetes, textiles, etc.). Otros sectores con aplicaciones generalizadas de ICP-MS son la fabricación de semiconductores y química fina, las ciencias de la vida, la investigación clínica, la geoquímica, la minería, la ciencia nuclear, la investigación de materiales, la metrología y el mundo académico.

Por qué SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con SUPEC-7000 Series Inductively Coupled Plasma Mass Spectrometry

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.

Productos relacionados

Envíe su consulta hoy mismo

Rellene el siguiente formulario y nos pondremos en contacto con usted en breve.

Información de contacto
Detalles del proyecto