Inicio / Producto / Analizador de gases por láser LGA-8100 (TDLAS)

Analizador de gases por láser LGA-8100 (TDLAS)

The LGA-8100 laser gas analyzer is based on tunable diode laser absorption spectroscopy (TDLAS) technology.
It can detect and analyze gas concentrations in harsh environments such as dusty and high temperatures and corrosive areas while maintaining a high level of safety, quick response time, high measurement accuracy, and ease of maintenance.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

The LGA-8100 laser gas analyzer is based on tunable diode laser absorption spectroscopy (TDLAS) technology.

It can detect and analyze gas concentrations in harsh environments such as dusty and high temperatures and corrosive areas while maintaining a high level of safety, quick response time, high measurement accuracy, and ease of maintenance.

Principio

The main components of LGA-8100 analyzer include laser transmitter, laser receiver, purging unit and junction box. The transmitting unit emits infrared light and uses an optical lens to guide the laser through the environment filled with the detection gas, then the receiver gather and reflects the infrared light carrying the optical information, and finally, the electronic component decodes the received signal into the gas concentration.

Analizador de gases por láser LGA-8100 (TDLAS) Especificaciones técnicas

Gama O: 0~1% Vol, 0~100% Vol. CH: 0~40ppm, 0~100% Vol.
CO/CO
: 0~1000ppm, 0~100% Vol.
H
O/HCl: 0~50ppm, 0~100% Vol.
H
S: 0~2000ppm, 0~100% Vol.
HF: 0~5ppm, 0~100% Vol. HCN: 0~30ppm, 0~100% Vol.
NH
/Cl: 0~10ppm, 0~100% Vol.
CH
I/CHO: 0~60ppm, 0~100% Vol.
Límite de detección O: 100ppm; CO/CO: 10ppm; HO: 0.3ppm; HS: 20ppm
HF: 0.02ppm; HCl/NH
/Cl: 0.1ppm; HCN: 0.3ppm
CH
: 0.4ppm; CHI/CHO: 0.6ppm
Precisión ±1%F.S.
Linearity Error ±1%F.S.
Repetibilidad ±1%F.S.
Deriva de la amplitud ≤1% / 6 per months
Tiempo de respuesta T90<1s
Explosion-Proof Level Ex d e IIC T6 Gb; Ex tD A21 IP66 T80°C
Clasificación del recinto IP66
Safety Integrity Level SIL2
Fuente de alimentación 24V DC
Potencia ≤20W
Salida 2-way, 4~20mA, Isolated
Communication Interfaces RS485, Ethernet, GPRS
Data Storage 24 days
Sample Gas Temperature 0~1400°C
Temperatura de trabajo -30~60°C
Purging Gas Purified air/industrial nitrogen

Aplicaciones versátiles en todos los sectores

Iron & steel, oil & gas, thermal power, etc.

Características principales de Analizador de gases por láser LGA-8100 (TDLAS)

With a low measurement drift and a high level of reliability.

With a high detection sensitivity and a high resistance to interference.

Onsite isolation design eliminates the requirement for positive pressure gas sources.

Enables real-time remote locking and range checking, enhancing the instrument’s stability.

Por qué Analizador de gases por láser LGA-8100 (TDLAS) Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con Analizador de gases por láser LGA-8100 (TDLAS)

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.

Envíe su consulta hoy mismo

Rellene el siguiente formulario y nos pondremos en contacto con usted en breve.

Información de contacto
Detalles del proyecto