Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.
El sistema FPI LGA es aplicable a casi todos los procesos industriales, especialmente bien probado en condiciones duras en combinación de alta temperatura, presión, polvo, corrosivos y contaminantes.
Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.
El sistema FPI LGA es aplicable a casi todos los procesos industriales, especialmente bien probado en condiciones duras en combinación de alta temperatura, presión, polvo, corrosivos y contaminantes.
Principio
TDLAS technology utilizes the principle that laser energy is absorbed selectively by gas to form an absorption spectrum. Laserbeams of specific wavelengths is emitted by semiconductorlaser, and when passes through the gas, the attenuation of the laserintensity is related with measured gas. The concentration can beobtained by measuring intensity attenuation.
| Parameter | Especificación |
|---|---|
| Componentes | O₂, CO, CO₂, H₂O, H₂S, HF, HCl, HCN, NH₃, CH₄, C₂H₂, C₂H₄, CH₃I |
| Precisión | HF: 0.02ppm; HCl, NH₃, C₂H₂: 0.1ppm; H₂O, HCN: 0.3ppm; CH₄: 0.4ppm; C₂H₄, CH₃I: 0.6ppm; CO, CO₂: 10ppm; H₂S: 20ppm; O₂: 100ppm. |
| Gama | HF: (0~5)ppm; C₂H₂, NH₃: (0~10)ppm; HCN: (0~30)ppm; CH₃I: (0~40)ppm; HCl, H₂O: (0~50)ppm; C₂H₄, CH₄: (0~60)ppm; CO, CO₂: (0~1000)ppm; H₂S: (0~2000)ppm; O₂: (0~1)%Vol., customized |
| Linealidad | ≤±1%F.S. |
| Deriva de la amplitud | ≤±1%F.S./6 meses |
| Repetibilidad | ≤±1%F.S. |
| Tiempo de respuesta | T₉₀≤20s (Flow rate more than 1 L/min) |
| Tiempo de precalentamiento | ≤15min |
| Temperatura de trabajo | -30~60°C |
| Temperatura de almacenamiento | -40~80°C |
| Gas de purga | Instrument air, industrial N₂ (0.3~0.8)Mpa |
| Presión de la muestra | 0.5~3bar |
| Temperatura de la muestra | -30~250°C |
| Tasa de cierre | IP65 |
| Explosion-Proof | Ex d IIC T5 |
| Fuente de alimentación | 100~240V AC |
| Consumo | ≤20W |
| Analog Inputs | 2 vías 4~20mA |
| Salidas analógicas | 2 way 4~20mA; isolation, maximum load 750Ω |
| Salidas de relé | 3 way relays, 24V/1A |
¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.
Tim Li
Gerente de Marketing
Tim Li