FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.

Descargas y recursos

Obtenga un presupuesto ahora
Descripción

Productos

FPI CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.

The system adopts a multi-gas analyzer to measure the concentration of SO₂, and NOx, by UV-DOAS method and concentration of CO and CO₂, by non-dispersive infrared (NDIR) module. The system also integrated internal maintenance and data process unit, which enables auto-calibration and online data transmission to minimize customer maintenance.

With decades of experience in CEMS research and development, FPI launched diverse and state-of-the-art analyzers which analyzers can be integrated into a complete continuous emission monitoring system. FPI can provide corresponding models for you to choose from below to meet different customers’ requirements for specific components monitoring.

Principio

CEMS-2000 continous emission monit-oring system adopts UV-DOAS technolgyDifferential Optical Absorption Spectroscopy (DOAS) is a kind ofspectrum monitortechnique. UV-DOAS can be defined as amethod ofdetermining gas concentrationby measuring specific narrow band abso-rption structures in the ultraviolet region.

Sistema de monitorización continua de emisiones CEMS-2000 (SO2, NOX, CO, CO2) Especificaciones técnicas

Principios UV-DOAS & NDIR
Componentes SO2, NOX, O2, CO, CO2
Temperatura (-20~50)℃
 

 

Gama

SO2: 0~26~5000 ppm

NO/NOX:0~75~2000 ppm

O2: 0~25%

CO: 0~1250mg/m³

Detection Limit CO2: 0~20%
Linealidad 1mg/m³
Span Drift ≤±1%F.S.
Zero Drift ≤±2%F.S./24h
Repetibilidad ≤±2%F.S./24h
Tiempo de respuesta ≤±1%
Power Supply UV-DOAS: ≤10s;  NDIR:≤30s
 

Salida

220VAC; 50~60Hz

4~20mA, RS232, RS485

Aplicaciones versátiles en todos los sectores

  • Thermal Power Plant
  • Oil&Gas Industry
  • Cement Plant
  • Metallurgy Industry
  • Fertilizer Plant

Características principales de Sistema de monitorización continua de emisiones CEMS-2000 (SO2, NOX, CO, CO2)

  • UV-DOAS technology allows simultaneous measurement of multiple gases, with comparative a better signal-noise ratio over conventional technology;
  • The hot-wet extractive sampling system avoids condensation, corrosion and chalking;
  • Modular system design reduces the maintenance cost and gives a more stable system performance;
  • User-friendly interface and software provide a non-attended operation experience;

Por qué Sistema de monitorización continua de emisiones CEMS-2000 (SO2, NOX, CO, CO2) Destaca

Preguntas frecuentes

Obtenga un presupuesto ahora

Desbloquee el análisis de precisión con Sistema de monitorización continua de emisiones CEMS-2000 (SO2, NOX, CO, CO2)

¿Está preparado para mejorar sus operaciones con soluciones de análisis en línea líderes en el sector? Póngase en contacto con nosotros para obtener asesoramiento experto, precios o una demostración personalizada.

Envíe su consulta hoy mismo

Rellene el siguiente formulario y nos pondremos en contacto con usted en breve.

Información de contacto
Detalles del proyecto