...
Home / Prodotto / Analizzatore di ossigeno, azoto e idrogeno ONH5000

Analizzatore di ossigeno, azoto e idrogeno ONH5000

ONH5000 Oxygen, Nitrogen and Hydrogen Analyzer is a high-performance analyzer for fast and accurate analysis of oxygen, nitrogen and hydrogen elements. The whole machine adopts modular and integrated design with six independent hardware module units, which is suitable for the determination of oxygen, nitrogen and hydrogen contents in ferrous metals, nonferrous metals, superconducting materials, semiconductor materials, rare earth materials, ceramic materials, refractory materials and other metallic and nonmetallic solid materials.

Download e risorse

Richiedi subito un preventivo
Descrizione

Panoramica del prodotto

ONH5000 Oxygen, Nitrogen and Hydrogen Analyzer is a high-performance analyzer for fast and accurate analysis of oxygen, nitrogen and hydrogen elements. The whole machine adopts modular and integrated design with six independent hardware module units, which is suitable for the determination of oxygen, nitrogen and hydrogen contents in ferrous metals, nonferrous metals, superconducting materials, semiconductor materials, rare earth materials, ceramic materials, refractory materials and other metallic and nonmetallic solid materials.

Principio

The ONH5000 Oxygen, Nitrogen, and Hydrogen Analyzer utilizes an inert gas-protected pulse furnace for melting and decomposition of samples. It measures oxygen via infrared absorption and nitrogen and hydrogen via thermal conductivity detection. The instrument is capable of simultaneously determining the content of oxygen, nitrogen, and hydrogen, or measuring each element individually as needed.

Equipped with an 8.0 kW pulse electrode furnace under inert gas protection, the ONH5000 achieves temperatures exceeding 3500°C. The furnace features program-controlled temperature ramping, with selectable power or current-controlled heating modes, ensuring complete and controlled sample decomposition. Depending on the target element, either helium or nitrogen is used as the carrier gas.

During high-temperature thermal decomposition:

  • Oxygen in the sample reacts with the graphite crucible to form carbon monoxide (CO)
  • Nitrogen and hydrogen are released in molecular forms as N₂ and H₂

The carrier gas transports these gases to a conversion furnace, where CO is oxidized to CO₂. The mixed gases then pass through the infrared detection system, where CO₂ is quantified. The remaining gas mixture (containing N₂ and H₂, with CO₂ removed) is routed to the thermal conductivity detector for the measurement of nitrogen and hydrogen.

Both detection systems (IR and TCD) amplify and convert the collected signals via A/D processing. These signals are then sent to the computer system for data analysis, calculating the oxygen, nitrogen, and hydrogen content in the sample with high precision.

Analizzatore di ossigeno, azoto e idrogeno ONH5000 Specifiche tecniche

Applicazioni versatili in tutti i settori industriali

Caratteristiche principali di Analizzatore di ossigeno, azoto e idrogeno ONH5000

Stable and Reliable Pulse Electrode Furnace System

  • Fully digital closed-loop control pulse electrode furnace

  • Programmable temperature ramping with multiple heating modes: constant power, constant current, constant voltage, and slope control

  • Higher precision temperature control ensures optimized melting and gas release performance

Circuit System

  • Modular design for both instrument control and data acquisition, with zero-drift architecture

  • Built on a 32-bit Reduced Instruction Set Computing (RISC) central processor architecture

  • Runs on uClinux operating system for faster, more stable performance

  • Independent channel acquisition prevents sequential sampling interference

Gas Circuit System

  • Fully integrated design with optimized layout for enhanced gas-tightness

  • All components made with imported, high-quality parts

  • Cylinder with dual-axis guide ensures smooth and stable electrode movement

  • Automatic sample dropping mechanism with gas curtain protection

  • Stable flow and pressure control, plus eco-mode standby for gas saving

Oxygen Detection System

  • Integrated solid-state infrared sensor for oxygen measurement; multiple IR cell ranges optional

  • Long-life precious metal miniature infrared light source, with no signal degradation over time

  • High-precision narrow-band optical filters and IR sensors

  • Full-range linear calibration with automatic temperature, pressure, and flow compensation

  • Optional imported IR detectors e dual infrared cells for enhanced sensitivity

Nitrogen and Hydrogen Detection System

  • High-sensitivity thermal conductivity detector (TCD) with high resistivity and large temperature coefficient

  • High-stability thermal conductivity unit using high-strength, low-noise hot-wire elements

  • Drift-free signal acquisition circuitry

  • Linear calibration technology enables a wider and more accurate detection range

Perché Analizzatore di ossigeno, azoto e idrogeno ONH5000 Si distingue

Domande frequenti

Richiedi subito un preventivo

Sblocca l'analisi di precisione con Analizzatore di ossigeno, azoto e idrogeno ONH5000

Sei pronto a migliorare le tue operazioni con soluzioni di analisi online leader del settore? Contattaci per ricevere assistenza da parte di esperti, informazioni sui prezzi o una demo personalizzata.

Invia oggi stesso la tua richiesta

Compila il modulo sottostante e ti ricontatteremo al più presto.

Informazioni di contatto
Dettagli del progetto