Home / Prodotto / Analizzatore di CO AQMS-400

Analizzatore di CO AQMS-400

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

Download e risorse

Richiedi subito un preventivo
Descrizione

Panoramica del prodotto

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.

Principio

Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

Analizzatore di CO AQMS-400 Specifiche tecniche

Gamma standard
(0~50)ppm, Expandable
Principio NDIR
Rumore zero ≤0.1ppm (RMS)
Rumore di campata ≤0.25ppm (RMS)
Limite inferiore rilevabile ≤0.04ppm (RMS)
Display 0.05ppm
Deriva zero ±0.1ppm
Deriva della campata <0.5% of reading
Linearità <1%F.S.
Precisione <1%
Tempo di risposta T90<60s
Portata del campione (800±80)sccm
Trasmissione dati 2 channel analog (4~20) mA;

12 digital input/output;

4-way relay output;

Communication RS232/RS485/Ethernet
Temperatura di esercizio US EPA Specification 20~30°C

Actual applicable:-5~55°C

Umidità di esercizio 0~95%RH
Calibrazione Calibratore multipunto
Requisiti di potenza 220V AC/50Hz;

110V AC/60Hz

Dimensioni e peso 178(H)x432(W)x597(D)mm, 28kg

Applicazioni versatili in tutti i settori industriali

Caratteristiche principali di Analizzatore di CO AQMS-400

  • 14 meters optical path to perform high reliability.
  • Five years guarantee on GFC wheel.
  • Compliance with US EPA reference method.
  • Various outputs include ethernet and RS232.
  • User friendly interface with large screen.
  • Diagnosi continua del sistema con allarme.
  • Multi-tasking software allows viewing test variables while operating;
  • Compensazione di temperatura e pressione.
  • Internal data logging with 1 min to 365 day multiple averages.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.

Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Data storage and analysis
Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.

Perché Analizzatore di CO AQMS-400 Si distingue

Domande frequenti

Richiedi subito un preventivo

Sblocca l'analisi di precisione con Analizzatore di CO AQMS-400

Sei pronto a migliorare le tue operazioni con soluzioni di analisi online leader del settore? Contattaci per ricevere assistenza da parte di esperti, informazioni sui prezzi o una demo personalizzata.

Invia oggi stesso la tua richiesta

Compila il modulo sottostante e ti ricontatteremo al più presto.

Informazioni di contatto
Dettagli del progetto