The LGA-8100 laser gas analyzer is based on tunable diode laser absorption spectroscopy (TDLAS) technology.
It can detect and analyze gas concentrations in harsh environments such as dusty and high temperatures and corrosive areas while maintaining a high level of safety, quick response time, high measurement accuracy, and ease of maintenance.
The LGA-8100 laser gas analyzer is based on tunable diode laser absorption spectroscopy (TDLAS) technology.
It can detect and analyze gas concentrations in harsh environments such as dusty and high temperatures and corrosive areas while maintaining a high level of safety, quick response time, high measurement accuracy, and ease of maintenance.
Grundsatz
The main components of LGA-8100 analyzer include laser transmitter, laser receiver, purging unit and junction box. The transmitting unit emits infrared light and uses an optical lens to guide the laser through the environment filled with the detection gas, then the receiver gather and reflects the infrared light carrying the optical information, and finally, the electronic component decodes the received signal into the gas concentration.
| Bereich | O₂: 0~1% Vol, 0~100% Vol. CH₄: 0~40ppm, 0~100% Vol. CO/CO₂: 0~1000ppm, 0~100% Vol. H₂O/HCl: 0~50ppm, 0~100% Vol. H₂S: 0~2000ppm, 0~100% Vol. HF: 0~5ppm, 0~100% Vol. HCN: 0~30ppm, 0~100% Vol. NH₃/Cl₂: 0~10ppm, 0~100% Vol. CH₃I/CH₂O: 0~60ppm, 0~100% Vol. |
| Nachweisgrenze | O₂: 100ppm; CO/CO₂: 10ppm; H₂O: 0.3ppm; H₂S: 20ppm HF: 0.02ppm; HCl/NH₃/Cl₂: 0.1ppm; HCN: 0.3ppm CH₄: 0.4ppm; CH₃I/CH₂O: 0.6ppm |
| Präzision | ±1%F.S. |
| Linearity Error | ±1%F.S. |
| Reproduzierbarkeit | ±1%F.S. |
| Span Drift | ≤1% / 6 per months |
| Reaktionszeit | T90<1s |
| Explosion-Proof Level | Ex d e IIC T6 Gb; Ex tD A21 IP66 T80°C |
| Gehäuse Bewertung | IP66 |
| Safety Integrity Level | SIL2 |
| Stromversorgung | 24V DC |
| Strom | ≤20W |
| Ausgabe | 2-way, 4~20mA, Isolated |
| Communication Interfaces | RS485, Ethernet, GPRS |
| Data Storage | 24 days |
| Messgas Temperatur | 0~1400°C |
| Arbeitstemperatur | -30~60°C |
| Purging Gas | Purified air/industrial nitrogen |
Iron & steel, oil & gas, thermal power, etc.
With a low measurement drift and a high level of reliability.
With a high detection sensitivity and a high resistance to interference.
Onsite isolation design eliminates the requirement for positive pressure gas sources.
Enables real-time remote locking and range checking, enhancing the instrument’s stability.
Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.