Startseite / Produkt / SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe)

SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe)

FPI SupNIR-2700 is the latest generation of self-developed benchtop NIR analyzer, designed for analysis in the food and agricultural industries. Its wavelength range covers 1000-2500 nm. With the help of computer software called RIMP, particles, flakes, powder samples, chemical components are rapidly detected while not affecting their chemical and physical composition. To carry out a test, all that is needed is to place the sample on the tray, click the ‘measure’ button, and automatically perform the analysis. It is widely used in feed production, grain and oil processing, breeding research, and other fields.

Downloads und Ressourcen

Jetzt ein Angebot einholen
Beschreibung

Produktübersicht

The SupNIR-2700 NIR analyser analyses samples in just 6 to 10 seconds and accurately determines moisture, protein, fat, ash, starch and many other parameters. Available factory calibration curves cover a wide range of products and parameters and are built into FPI’s global database of hundreds of thousands of samples.

 

Operations and Handling:

The SupNIR-2700 has been designed in accordance with the customer’s intended mode of operation, with the objective of reducing the learning curve for laboratory personnel and streamlining the analysis process, thereby reducing the time required for staff to complete their tasks.

The procedure is straightforward and comprises four simple steps:
1. Switch on the machine and allow it to warm up for 30 seconds.
2. Pour the sample into the sample tray.
3. Place the sample tray into the SupNIR-2700.

4. Select the product from the list displayed on the touch screen.

Once these steps have been completed, the analysis will commence automatically, and a comprehensive set of results will be displayed in a few seconds.

SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe) Technische Daten

Wellenlängenbereich 1000~1800nm, SupNIR-2720
1000~2500nm, SupNIR-2750
Noise Less than 5×10⁻⁵A
Wavelength Accuracy ±0.2nm
Wavelength Repeatability Less than 0.01nm
Stray Light Less than 0.1%
Auflösung 10.95±0.3nm@1295.5nm
Analysis Time Less than 60s
Simultaneous Analysis No limit
Sample Size Less than 120g
Lamp Lifetime More than 5000 hours
Communication Ports USB2.0
Temperature (5~35)℃
Humidity (5~85)%RH
Stromversorgung (198~242)V; 50Hz; 0.5A
Dimension(LxWxH) 403x391x374mm
Gewicht ≈20kg

Vielseitige Anwendungen in verschiedenen Branchen

Oilseed Extraction
The SupNIR-2700 NIR instrument is suitable for all seeds such as oilseeds, feed, and oil for analyzing moisture, fat, fatty acids, protein, and other parameters.
  • Detect seeds to analyze its quality
  • Analyze feed for optimized extraction, drying, and blending
  • Determine free fatty acids, phosphorus, etc., in the oil

Flour Processing

The SupNIR-2700 near-infrared (NIR) instrument is capable of analysing a range of characteristics in wheat and flour, including moisture content, protein content, ash content, and more.

  • The instrument can be used to detect wheat at the intake and tempering stages.
  • Ash content can be optimised quickly and accurately through analysis.

Breeding

The combination of accuracy and speed of analysis makes the SupNIR-2700 an ideal choice for breeding companies and research institutes. It is capable of analysing standard grain or oilseed parameters, including moisture, protein, and oil content, as well as special characteristics such as fatty acid composition and amino acid levels. The SupNIR-2700 is used by leading research institutions and companies worldwide.

Hauptmerkmale von SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe)

  • Easy to operation, no special training and sample pre-treatment is required, and the analyzer will not destroy the samples;
  • The analysis speed is fast, and multiple indexes, such as moisture, fat, protein, fiber, ash, amino acid and so on, can be detected simultaneously within one minute;
  • Suitable for a variety of sample shapes (granular, flake and powder);
  • With built-in standard material, with automatic diagnosis and fault warning function;

Warum SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe) Stellt sich heraus

Häufig gestellte Fragen

Jetzt ein Angebot einholen

Erschließen Sie die Präzisionsanalyse mit SupNIR-2700 Tischgerät für Nahinfrarotanalyse (Feuchtigkeit, Protein, Fett/Öl, Asche, Ballaststoffe)

Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.

Senden Sie noch heute Ihre Anfrage

Füllen Sie das untenstehende Formular aus, und wir werden uns in Kürze mit Ihnen in Verbindung setzen.

Kontaktdaten
Projektdetails