LGA-4500 Bypass-Analysator für abstimmbare Diodenlaser (TDL)

Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.

FPI LGA system is applicable to almost all industrial process, especially well proven in harsh conditions in combination of high temperature, pressure, dust, corrosives and contaminants.

Downloads und Ressourcen

Jetzt ein Angebot einholen
Beschreibung

Produktübersicht

Utilizing proprietary technologies of Tunable Diode Laser Absorption Spectroscopy (TDLAS), FPI delivers the LGA system to satisfy in-situ measurements with high accuracy, fast response, strong reliability and virtually maintenance free.

FPI LGA system is applicable to almost all industrial process, especially well proven in harsh conditions in combination of high temperature, pressure, dust, corrosives and contaminants.

Grundsatz

TDLAS technology utilizes the principle that laser energy is absorbed selectively by gas to form an absorption spectrum. Laserbeams of specific wavelengths is emitted by semiconductorlaser, and when passes through the gas, the attenuation of the laserintensity is related with measured gas. The concentration can beobtained by measuring intensity attenuation.

LGA-4500 Bypass-Analysator für abstimmbare Diodenlaser (TDL) Technische Daten

 

Parameter Specification
Komponenten O₂, CO, CO₂, H₂O, H₂S, HF, HCl, HCN, NH₃, CH₄, C₂H₂, C₂H₄, CH₃I
Genauigkeit HF: 0.02ppm; HCl, NH₃, C₂H₂: 0.1ppm; H₂O, HCN: 0.3ppm; CH₄: 0.4ppm; C₂H₄, CH₃I: 0.6ppm; CO, CO₂: 10ppm; H₂S: 20ppm; O₂: 100ppm.
Bereich HF: (0~5)ppm; C₂H₂, NH₃: (0~10)ppm; HCN: (0~30)ppm; CH₃I: (0~40)ppm; HCl, H₂O: (0~50)ppm; C₂H₄, CH₄: (0~60)ppm; CO, CO₂: (0~1000)ppm; H₂S: (0~2000)ppm; O₂: (0~1)%Vol., customized
Linearität ≤±1%F.S.
Span Drift ≤±1%F.S./6 months
Reproduzierbarkeit ≤±1%F.S.
Reaktionszeit T₉₀≤20s (Flow rate more than 1 L/min)
Preheating Time ≤15min
Arbeitstemperatur -30~60°C
Storage Temperature -40~80°C
Purge Gas Instrument air, industrial N₂ (0.3~0.8)Mpa
Sample Pressure 0.5~3bar
Sample Temperature -30~250°C
Enclosing Rate IP65
Explosion-Proof Ex d IIC T5
Stromversorgung 100~240V AC
Consumption ≤20W
Analog Inputs 2 way 4~20mA
Analog Outputs 2 way 4~20mA; isolation, maximum load 750Ω
Relay Outputs 3 way relays, 24V/1A

 

Vielseitige Anwendungen in verschiedenen Branchen

  • HCl, HF in waste incineration.
  • NH3 and HF monitoring in fertilizer plant.
  • HCl in pharma industry.
  • NH3 slip in thermal power plant SCR, SNCR.

Hauptmerkmale von LGA-4500 Bypass-Analysator für abstimmbare Diodenlaser (TDL)

  • Monochromaticity with the spectral width down to 0.001nm ensures high precision and anti-interference from the background.
  • Maintenance-free with cross-stack alignment.
  • IECEx ex-proof suitable for adoption of the system in hazardous areas.
  • Auto drift correction extends calibration interval up to 1 year.

Warum LGA-4500 Bypass-Analysator für abstimmbare Diodenlaser (TDL) Stellt sich heraus

Häufig gestellte Fragen

Jetzt ein Angebot einholen

Erschließen Sie die Präzisionsanalyse mit LGA-4500 Bypass-Analysator für abstimmbare Diodenlaser (TDL)

Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.

Verwandte Produkte

Senden Sie noch heute Ihre Anfrage

Füllen Sie das untenstehende Formular aus, und wir werden uns in Kürze mit Ihnen in Verbindung setzen.

Kontaktdaten
Projektdetails