Home / Prodotto / Analizzatore di CO2 AQMS-450

Analizzatore di CO2 AQMS-450

FPI AQMS-450 carbon dioxide (CO2) analyzer measures ambient CO2 concentration by employing Non-dispersive infrared (NDIR) with gas filter correlation (GFC) method technology to realize ppm level CO2 concentration measurement.

Download e risorse

Richiedi subito un preventivo
Descrizione

Panoramica del prodotto

FPI AQMS-450 carbon dioxide (CO2) analyzer measures ambient CO2 concentration by employing Non-dispersive infrared (NDIR) with gas filter correlation (GFC) method technology to realize ppm level CO2 concentration measurement.

Principio
Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.
Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Data storage and analysis

Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.

Analizzatore di CO2 AQMS-450 Specifiche tecniche

Gamma standard

0~2000ppm

Rumore zero

≤0.1ppm

Rumore di campata

≤5ppm

Limite inferiore rilevabile

<0.2ppm

Precisione

≤5ppm

Tempo di risposta

≤90s (T90)

Uscita

4~20mA,

RS232, RS485, Ethernet

Applicazioni versatili in tutti i settori industriali

Caratteristiche principali di Analizzatore di CO2 AQMS-450

  • The integrated purging device which eliminates the interference of environmental CO2 to the instrument measurement.
  • The White cavity design and special anti-corrosion technology on the surface of optical devices to give better stability and longer lifetime.
  • Wide measurement range with low detection limit, which can meet the needs of CO2 monitoring in most application.
  • Adopting GFC NDIR technology, measuring range is up to 2000 ppm.
  • High response, high repeatability, high accuracy and simple operation.
  • Support classified operation, automatically storing the calibration data and alarm information, etc.

Perché Analizzatore di CO2 AQMS-450 Si distingue

Domande frequenti

Richiedi subito un preventivo

Sblocca l'analisi di precisione con Analizzatore di CO2 AQMS-450

Sei pronto a migliorare le tue operazioni con soluzioni di analisi online leader del settore? Contattaci per ricevere assistenza da parte di esperti, informazioni sui prezzi o una demo personalizzata.

Invia oggi stesso la tua richiesta

Compila il modulo sottostante e ti ricontatteremo al più presto.

Informazioni di contatto
Dettagli del progetto