LDM-200 is a new extractable low-concentration particulates monitoring system, which can beapplied to measure low-concen-tration particulates after wet des-ulfurization and wet dustremoval in coal-fired power plants.
This instrument is based on the extractive scattering measurement principle and has extremelyhigh sensitivity. lt can reliably measure the concentration of particulates in the wet flue gasthrough the whole process of heat tracing sampling and the flue gas pretreatment module.
| Princípio | High temperature extraction isokinetic sampling; Scattering |
|---|---|
| Gama de medição | Minimum range 0~5mg/m³; Maximum range 0~200mg/m³ |
| Limite de deteção | 0.1mg/m³ |
| Tempo de resposta | <15min |
| Desvio zero | ±2%F.S./24h |
| Desvio de alcance | ±2%F.S./24h |
| Flue Gas Humidity | Up to 100% RH |
| Constant Velocity Tracking Range | 5~40m/s |
| Total Flow of Sampling System | 5~15L/min (Adjustable) |
| Protection Level | IP65 |
| Peso | 22kg |
| Saída | 4~20mA, RS485 |
| Fonte de alimentação | 220V AC, 50Hz |
Pronto para melhorar as suas operações com soluções de análise online líderes do setor? Entre em contacto para obter orientação especializada, preços ou uma demonstração personalizada.