D. O. Sensor

The dissolved oxygen online sensor uses the fluorescence method to detect dissolved oxygen in water. It features a built-in temperature sensor for automatic temperature compensation. Manual compensation for atmospheric pressure and salinity is available, with one-button switching between national and industry standards. The sensor uses an RS485 interface and supports the standard Modbus protocol.

Downloads und Ressourcen

Jetzt ein Angebot einholen
Beschreibung

Produktübersicht

During the interaction between dissolved oxygen in water and fluorescent substances, both the fluorescence intensity decreases and the fluorescence lifetime shortens. This fluorescence quenching can be described by the Stern–Volmer equation:

Wo:

  • I0I_0 — Fluorescence intensity in the absence of oxygen
  • II — Fluorescence intensity in the presence of oxygen
  • τ0 au_0 — Fluorescence lifetime in the absence of oxygen
  • τ au — Fluorescence lifetime in the presence of oxygen
  • [O2][O_2] — Oxygen concentration
  • KK — Stern–Volmer constant

D. O. Sensor Technische Daten

Product model DO-200 DO-210 DO-230
Working principle Fluorescence method Fluorescence method Fluorescence method
Measurement range (0~20)mg/L &can be customized (0~20)mg/L &can be customized (0~20)mg/L &can be customized
Wiederholbarkeit ±0.2mg/L ±0.2mg/L ±0.2mg/L
Measurement accuracy ±0.2mg/L ±0.2mg/L ±0.2mg/L
Drift (24h) ±0.2mg/L ±0.2mg/L ±0.2mg/L
Entschließung 0.01mg/L 0.01mg/L 0.01mg/L
Reaktionszeit <1min <1min <1min
Protection level IP68 IP68 IP68
Communication interface RS485, standard Modbus protocol baud rate 4800, 9600, 19200, 38400, 57600, 115200 RS485, standard Modbus protocol baud rate 4800, 9600, 19200, 38400, 57600, 115200 RS485, standard Modbus protocol baud rate 4800, 9600, 19200, 38400, 57600, 115200
Abmessungen (φ33*224)mm, cable 10 meters (can be customized) (φ12*115)mm, cable 10 meters (can be customized) Φ12*220mm
Material 316L stainless steel /PVC/ titanium alloy 316L stainless steel/titanium alloy 316L stainless steel
Gewicht 0.5kg 0.1kg 0.1kg
Mounting threads Upper end NPT3/4 thread / VP8 fittings & PG13.5 threads
Operating voltage (9~36)V DC (9~36)V DC (9~36)V DC
Energy consumption 0.4 W 0.4 W 0.4 W
MTBF ≥1440h/time ≥1440h/time Membrane cap high temperature sterilization 30pcs
Calibration period 6 ~ 12 months 6 ~ 12 months 6 ~ 12 months
Work environment (0~50) °C (0~50) °C 0~130℃

Vielseitige Anwendungen in verschiedenen Branchen

  • Oberflächenwasser
  • Municipal sewage
  • Aquaculture water
  • Bioreactors (fermentation tanks)

Hauptmerkmale von D. O. Sensor

  • No need to replace the oxygen membrane or electrolyte, resulting in low maintenance
  • Utilizes fluorescence detection technology for fast response
  • Equipped with temperature compensation, suitable for a wide range of environments
  • Korrosionsbeständiges Gehäuse mit Wasserdichtigkeitsklasse IP68 für langfristigen Unterwasserbetrieb
  • RS485-Kommunikationsschnittstelle mit Standard-Modbus-Protokoll für einfache Integration

Warum D. O. Sensor Stellt sich heraus

Häufig gestellte Fragen

Jetzt ein Angebot einholen

Erschließen Sie die Präzisionsanalyse mit D. O. Sensor

Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.

Senden Sie noch heute Ihre Anfrage

Füllen Sie das untenstehende Formular aus, und wir werden uns in Kürze mit Ihnen in Verbindung setzen.

Kontaktdaten
Projektdetails