ホーム / 製品 / FMS-100 ホルムアルデヒドオンライン監視システム

FMS-100 ホルムアルデヒドオンライン監視システム

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

ダウンロードとリソース

今すぐ見積もりを取得
説明

製品概要

In recent years, mobile vehicle exhaust and industrial emissions of organic compounds VOCs are increasing, causing atmospheric photochemical smog pollution. Formaldehyde is highly reactive in the atmosphere, and it can generate HO2 radicals through photolysis, and HO2 radicals react rapidly with NO to generate OH radicals, so formaldehyde becomes an important source of atmospheric OH radicals.

 

The FMS-100 detects formaldehyde in air based on the fluorometric method and the Hantzsch reaction principle. The reaction is carried out quantitatively. In the presence of ammonia, formaldehyde reacts with acetylacetone to produce 3,5-diacetyl-1,4-dihydropyridine (DDL), which is excited by UV and the concentration of formaldehyde is determined by monitoring the fluorescence intensity with a photomultiplier tube.

 

FMS-100 ホルムアルデヒドオンライン監視システム 技術仕様

検出限界 <50ppt
Measurement of Substances Formaldehyde in air and liquid
精度 <10%
再現性 RSD<5%
範囲 50ppt~3ppm
Linear Correlation Coefficient R>0.99
Absorption Efficiency 100%
Time Resolution Seconds/Minutes(Optional)

多様な産業分野での応用

  • Formaldehyde concentration monitoring in ambient air.
  • Atmospheric photochemical smog pollution warning system.
  • Atmospheric environment complex pollution research.

主な特徴 FMS-100 ホルムアルデヒドオンライン監視システム

  • Low detection limit, with a detection limit of <50ppt.
  • Absorption module with 100% capture efficiency for accurate monitoring for formaldehyde concentration.
  • It can achieve high-precision temperature control of each module of the system (±0.1°C) to ensure the accuracy of the measurement results.
  • Autonomous adjustment of the instrument’s time resolution at the second/minute level.
  • Visualization of formaldehyde concentration trends over time.
  • The gas-liquid separation adopts the unique flow path design to ensure real-time measurement results.