PFS-100 Photolyse-Analysator

Photolytic rate of some critical reactant and free radical (O(1D), NO2, H2O2, HONO, HCHO etc.) are key indicators for identify status & extent of photochemical pollution.The analyzer is receiving solar radiation by quartz probe and transferring the radiation to spectrum via optical quartz fiber, the spectrum data will be evaluated and compared with reference data with mathematical approach and gives photolytic rate.

Downloads und Ressourcen

Jetzt ein Angebot einholen
Beschreibung

Produktübersicht

Photolytic rate of some critical reactant and free radical (O(1D), NO2, H2O2, HONO, HCHO etc.) are key indicators for identify status & extent of photochemical pollution.The analyzer is receiving solar radiation by quartz probe and transferring the radiation to spectrum via optical quartz fiber, the spectrum data will be evaluated and compared with reference data with mathematical approach and gives photolytic rate.

PFS-100 Photolyse-Analysator Technische Daten

Quartz Receiver Head Angular response deviation within ±5% in each direction of the hemisphere (2π sr)
Measurement Components J(O1D), J(HCHO-M), J(HCHO-R), J(NO₂), J(H₂O₂), J(HONO), J(NO₃-M), J(NO₃-R)
Spectral band range 270~790NM
Spectral resolution <0.75~0.85nm(FWHM)
Measurement method Online continuous
Spectral scan Combining the results of different integration time spectral scans
Sampling time setting Self-setting measurement time
Dark noise calibration Dark noise calibration of data within a certain period

Vielseitige Anwendungen in verschiedenen Branchen

Hauptmerkmale von PFS-100 Photolyse-Analysator

  • Spectrograph detection using a spectrometer with a cooled CCD detector.
  • High resolution and sensitivity of spectral measurement.
  • Further improve the signal-to-noise ratio of spectral measurements by combining the spectral information of different integration times.
  • Ability to convert spectral detection into photochemical flux measurements based on factory calibrated instrument parameters.
  • The photolysis rate constants of multiple substances can be obtained simultaneously by combining the results of real-time spectroscopy measurements.
  • Simple instrument structure, fast response time, independent build calibration platform, can provide calibration services.

Warum PFS-100 Photolyse-Analysator Stellt sich heraus

Häufig gestellte Fragen

Jetzt ein Angebot einholen

Erschließen Sie die Präzisionsanalyse mit PFS-100 Photolyse-Analysator

Sind Sie bereit, Ihre Abläufe mit branchenführenden Online-Analyselösungen zu verbessern? Setzen Sie sich mit uns in Verbindung, um fachkundige Beratung, Preise oder eine persönliche Demo zu erhalten.

Senden Sie noch heute Ihre Anfrage

Füllen Sie das untenstehende Formular aus, und wir werden uns in Kürze mit Ihnen in Verbindung setzen.