AQMS-700 CAPS NO2分析装置

AQMS-700 CAPS NO2 analyzer is an atmospheric environment monitoring instrument based on the optical cavity attenuation phase shift technology (CAPS) which can directly measure the NO2 concentration in the ambient air and is widely used in the online monitoring of the NO2 content in the ambient air quality monitoring scene.

ダウンロードとリソース

今すぐ見積もりを取得
説明

製品概要

AQMS-700 CAPS NO2 analyzer is an atmospheric environment monitoring instrument based on the optical cavity attenuation phase shift technology (CAPS) which can directly measure the NO2 concentration in the ambient air and is widely used in the online monitoring of the NO2 content in the ambient air quality monitoring scene.

The analyzer is mainly composed of pre-processing module, resonant cavity module, flow control module, circuit module, etc., and will measure the gas concentration according to the phase difference between the beam in the reference cavity and the cavity with NO2. The LED beam is modulated by high frequency signal and coupled into the optical cavity composed of high-reflection mirror. Then, beam is reflected repeatedly in the cavity and is absorbed by NO2 in the cavity. The absorbed beam is collected by the detector after passing through the optical cavity and the optical filter. The detector converts the optical signal into electrical signal, then demodulates it by electrical heterodyne method, and finally obtains the signal with phase information.

AQMS-700 CAPS NO2分析装置 技術仕様

範囲 

0~500ppb to 0~1000ppb,

Optional dual range and auto range

Measurement Units

ppb, ppm, μg/m3, mg/m3 (optional)

検出下限値

≤0.2ppb(RMS)

ゼロ・ノイズ

≤0.1ppb(RMS)

スパン・ノイズ

≤0.5%F.S.

Indication Error

±1%F.S.

Precision(20%) 

≤1% Reading value

Precision(80%)

≤1% Reading value

多様な産業分野での応用

  • Atmospheric background station, urban environment and other conventional monitoring;
  • Laboratory ultra-high requirement monitoring;
  • NO2 concentration monitoring in special areas such as hospitals;

主な特徴 AQMS-700 CAPS NO2分析装置

  • Adopt ultra-high reflector, low detection limit.
  • Direct measurement, without reagent or catalytic conversion, low maintenance.
  • Strong anti-interference ability.
  • Simple structure and parts.
  • Strong system stability, low power consumption.
  • Fast response time.

なぜ AQMS-700 CAPS NO2分析装置 際立つ