ポータブルアナライザー

Focused Photonics Inc. (FPI) enables field-ready water assessment with its Portable Analyzer series, providing handheld, multi-parameter detection of turbidity, pH, COD, ammonia, and ions in rivers, lakes, and effluents. The SIA and portable series utilize light scattering, UV absorbance, and ISE technologies for compliance with ISO 7027, GB 3838-2002, and EPA Method 180.1.

Field Audit: Principles of Portable Detection

Portable analyzers quantify water parameters through miniaturized optics and electrochemistry for instant, on-site validation. FPI’s tools employ Nephelometric light scattering at 90° for turbidity (0-1000 NTU, ±1 NTU), UV absorbance at 254 nm for COD (0-500 mg/L, ±0.1 mg/L), and ISE for ions/pH (0-14, ±0.01), per ISO 7027.

Principles of Portable Detection

Evolved from 1990s pocket meters, these analyzers integrate GPS logging and Bluetooth for data sharing. FPI refines with anti-fouling probes and 8-hour batteries (-10°C to 50°C), ensuring <2% drift per GB 3838-2002. In 2025’s mobile monitoring surge, our portables fuse with apps for GIS mapping, informing EPA field audits and SDG 6 water access.

FPI Portable Analyzers in Field Action

FPI's portables equip 6,000+ field teams, with 1,500+ units deployed annually, enabling rapid ecosystem surveys.

FPIのIoTダッシュボードを介したこれらのアプリケーションは、5つ以上の国家水指令をサポートし、SDG6を推進している。.

FPI's Portable Vigilance: Precision in the Field

With 22 years of handheld innovation, 888+ patents, and IP67 certifications, FPI's analyzers prioritize mobility and accuracy, offering 30% faster readings than lab kits.

Parameter Spectrum
Field Resilience
データ・フュージョン
エコデザイン
グローバル・アライアンス

Field Foundations: Unpacking FPI's Portable Detection

FPI’s analyzers trace water signals through layered precision:

  1. インテークの準備: Dip probe or pump sample, filtering particulates for clean optics.
  2. シナジーを感知する: Scattering/UV/ISE modules quantify parameters in <30s.
  3. Data Refinement: On-device AI compensates for temperature, outputting via Bluetooth.
  4. インサイト配信: App dashboards map results, exporting to GIS for reports.

This portable pathway, shown in our handheld schematics, ensures vigilant field insights.

Portable Techniques Table: FPI’s Detection Diversity

 
 
技法パラメータ感度展開適合性FPI強化
光散乱濁度1 NTU河川ドリフトのないオートゼロ調整
紫外線吸収率代金引換0.1 mg/LEffluentsPortable LED source
ISEIons, pH0.05 mg/LPondsMiniaturized electrodes
Chemical DPDChlorine0.02 mg/LField testsReagent-free options
 

FPI’s portables power 2025’s mobile imperatives.

Ecosystem Catalysts: Broader Impacts of FPI Analyzers

FPI portables catalyze action: In spills, they cut exposure by 30%; in surveys, save 20% lab costs. With open apps and low-SWaP, our tools foster citizen science, refining 25% of field indices for SDG 6.

Portable Queries: Six Field Answers

How do FPI portables achieve NTU accuracy in muddy rivers?

90° scattering with auto-zeroing corrects for bubbles, maintaining ±1 NTU per ISO 7027.

254 nm LED absorbance quantifies organics with 90% accuracy, battery-powered for 8 hours.

Membranes reject Cl-, achieving ±0.05 mg/L for NH4+ per ISO 17294.

Bluetooth exports turbidity/COD to GIS apps, enabling 18% faster hotspot identification.

NIST-traceable ISEs yield <0.3 mg/L bias for heavy metals, per EPA 200.7.

IP67 casings with 1m drop resistance sustain <2% drift in 50°C humidity, per ASTM D4169.

折り返し電話をリクエスト

弊社のサービスに関してご質問がございましたら、下記のお問い合わせフォームよりご記入ください。.

今すぐお問い合わせください

以下のフォームにご記入ください。折り返しご連絡いたします。.

連絡先情報
プロジェクト詳細