ホーム / 製品 / CEMS-2000 B FT 全パラメータ監視システム(SO2、NOX、NH3、CO、CO2、H2O、HCI、HF)

CEMS-2000 B FT 全パラメータ監視システム(SO2、NOX、NH3、CO、CO2、H2O、HCI、HF)

FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.

ダウンロードとリソース

今すぐ見積もりを取得
説明

製品概要

FPI CEMS-2000 B FT system consists of FTIR (Fourier Transform Infrared) interferometer and heat tracing sampling system. The system targets multiple gas monitoring applications such as pharma industry and incinerator emission, which has a complex flue matrix including toxic parameters. The FTIR interferometer enhances the absorption signal while removing the background interference, hence detecting trace level gas in the sample matrix, especially for HF and HCI.

FPIはCEMS研究開発における数十年の経験により、多様で最先端の分析器を発売し、分析器は完全な連続排出監視システムに統合することができます。FPIは、特定のコンポーネントを監視するためのさまざまな顧客の要件を満たすために、以下の中から選択するために対応するモデルを提供することができます。.

原則

This system adopts FTlR technology. lt is akind of measurement technique that usesan interferometer to generate an interfer-ence pattern, and then converts it into aninfrared spectroscopy. The infrared spec-trometer is to measure the energy changebetween the vibrational and rotational en-ergy states caused by the absorption ofinfrared light by the substance, so that toperform qualitative and quantitative anal-ysis of samples.

CEMS-2000 B FT 全パラメータ監視システム(SO2、NOX、NH3、CO、CO2、H2O、HCI、HF) 技術仕様

原則 FTIR Spectroscopy
コンポーネント SO₂, NOₓ, O₂, CO, CO₂, HCl, HF, NH₃, H₂O, temperature, flow, pressure, humidity
温度 (18~35)°C
Range(mg/m³) SO₂:0~75~2000; NO:0~100~2000; NO₂:0~50~1000; NOₓ:0~100~2000; NH₃:0~10~50; HCl:0~15~1500; HF:0~10~50; CO:0~75~1000; CO₂:0~20%; H₂O:0~40%; O₂:0~25%;
Lower Detection Limit(mg/m³) SO₂:0.45; NO:0.8; NO₂:0.4; NH₃:0.1; HCl:0.35; HF:0.25; CO:0.2; CO₂:0.025%; H₂O:0.1%;
直線性 ≤±2%F.S.
スパン・ドリフト ≤±2%F.S./7d
ゼロドリフト ≤±2%F.S./7d
PM Measuring Distance 0.7~20m
PM Measuring Range 0~100~1000mg/m³
PM Measuring Precision 2%F.S.
応答時間 SO₂, NOₓ, CO, CO₂≤180s (50m); HCl, HF, NH₃≤300s;
電源 220VAC/50Hz 2KW (without sampling line, compressor)
出力 Analog, Ethernet connection, RS485, GPRS, System on-off, DP (optional)

多様な産業分野での応用

  • Solid Waste Incineration
  • Sludge Incineration
  • Cement Kiln Co-processing of Hazardous Waste
  • Biomass Incineration
  • Coal, Oil, Gas Power Plants

主な特徴 CEMS-2000 B FT 全パラメータ監視システム(SO2、NOX、NH3、CO、CO2、H2O、HCI、HF)

  • Latest FTIR technology adopted in scientific-analytical application measures maximum parameters with only one analyzer.
  • White cavity gas cell extends the optical path up to 5 meters that ensures high analysis sensitivity.
  • 180-degree temperature heat tracing throughout the system avoid condensation.
  • User-friendly interface and software provide non-attended operation experience.

なぜ CEMS-2000 B FT 全パラメータ監視システム(SO2、NOX、NH3、CO、CO2、H2O、HCI、HF) 際立つ