FPI CEMS provides application gas analysis solution, integrated with Particulate Monitoring Subsystem, TPF Monitoring Subsystem, Gaseous (Pollutant) Monitoring Subsystem, Data Acquisition and Processing Subsystem, covering all the indicators and parameters to meet different customers’ needs. Such systems are extensively installed in industrial boilers, indicators and other emission sources with real-time data uploaded to local authorities.
FPI CEMS-2000 B FT system consists of FTIR (Fourier Transform Infrared) interferometer and heat tracing sampling system. The system targets multiple gas monitoring applications such as pharma industry and incinerator emission, which has a complex flue matrix including toxic parameters. The FTIR interferometer enhances the absorption signal while removing the background interference, hence detecting trace level gas in the sample matrix, especially for HF and HCI.
بفضل خبرتها التي تمتد لعقود في مجال البحث والتطوير في أنظمة مراقبة الانبعاثات المستمرة (CEMS)، أطلقت FPI أجهزة تحليل متنوعة ومتطورة يمكن دمجها في نظام مراقبة انبعاثات مستمر وكامل. توفر FPI نماذج مناسبة يمكنك الاختيار من بينها أدناه لتلبية متطلبات العملاء المختلفة لمراقبة مكونات محددة.
المبدأ
This system adopts FTlR technology. lt is akind of measurement technique that usesan interferometer to generate an interfer-ence pattern, and then converts it into aninfrared spectroscopy. The infrared spec-trometer is to measure the energy changebetween the vibrational and rotational en-ergy states caused by the absorption ofinfrared light by the substance, so that toperform qualitative and quantitative anal-ysis of samples.
| المبدأ | FTIR Spectroscopy |
|---|---|
| المكونات | SO₂, NOₓ, O₂, CO, CO₂, HCl, HF, NH₃, H₂O, temperature, flow, pressure, humidity |
| درجة الحرارة | (18~35)°C |
| Range(mg/m³) | SO₂:0~75~2000; NO:0~100~2000; NO₂:0~50~1000; NOₓ:0~100~2000; NH₃:0~10~50; HCl:0~15~1500; HF:0~10~50; CO:0~75~1000; CO₂:0~20%; H₂O:0~40%; O₂:0~25%; |
| Lower Detection Limit(mg/m³) | SO₂:0.45; NO:0.8; NO₂:0.4; NH₃:0.1; HCl:0.35; HF:0.25; CO:0.2; CO₂:0.025%; H₂O:0.1%; |
| الخطية | ≤±2%F.S. |
| انجراف المسافة | ≤±2%F.S./7d |
| انحراف صفر | ≤±2%F.S./7d |
| PM Measuring Distance | 0.7~20m |
| PM Measuring Range | 0~100~1000mg/m³ |
| PM Measuring Precision | 2%F.S. |
| وقت الاستجابة | SO₂, NOₓ, CO, CO₂≤180s (50m); HCl, HF, NH₃≤300s; |
| مصدر الطاقة | 220VAC/50Hz 2KW (without sampling line, compressor) |
| الناتج | Analog, Ethernet connection, RS485, GPRS, System on-off, DP (optional) |